The output voltage can be increased by the serial operation, while the output current can be increased by parallel operation. A one-control serial operation can be used to control several slave power supplies from one master power supply. (One-control operation is possible only for the PAS-R series.)
Output sensor terminal installed (only for the PAS-R series) under consideration of the necessity for fine setting of the load terminal voltage, an output sensor terminal has been provided on the panel surface.
Systemization by correspondence to various remote-control methods (only for the PAS-R series)
A remote-control terminal is provided for output ON/OFF by means of an external contact signal, and remote control of output voltage and the output current is possible by an external voltage of 0 to 10V and an input resistance of 0 to 10K Ω respectively.
Item
PAS2030/R
PAS3020/R
PAS3030/R
PAS6010R
Output
Output voltage
0 to 20V
0 to 30V
0 to 60V
Voltage setting knob
with coarse / fine adjustment
1 revolution / 1 revolution
Output current
0 to 3A
0 to 2A
0 to 3A
0 to 1A
Constant voltage characteristics (CV)
Input regulation
For AC ± 10% fluctuation
4mV
5mV
8mV
Load regulation
For 0 to 100% fluctuation
4mV
5mV
8mV
Ripple and noise
10Hz to 1MHz
0.5mV rms
1mV rms
Ripple peak
10Hz to 20MHz
3mV p-p
4mV p-p
Transient response
Standard value (current 5% to 100%)
50 μ Typical x 1
Temperature coefficient
standard value
100ppm / °C Typical
Remote Control
External Voltage / Output Voltage ratio PAC-R Series
10V / 20V ± 5%
10V/30V ±5%
10V/60V ±5%
Remote Control
External Resistance / Output Voltage ratio PAC-R Series
10K Ω / 20V ± 5%
10V/30V ±5%
10K Ω /60V ±5%
Constant Current Characteristics (CC)
Input regulation
For AC ± 10% fluctuation
3mA
2mA
3mA
2mA
Long regulation
For 0 to 100% fluctuation
10mA
Ripple and noise
10Hz to 1MHz
2mA rms
1mA rms
#1: The transient response denotes the response time until the voltage is stabilized when the output switch activated(on).
Item
PAS2030/R
PAS3020/R
PAS3030/R
PAS6060/R
Temperature coefficient
standard value
250ppm/ °C Typical
Remote control
External voltage / output current ratio PAC-R series
10V/3A ±5%
10V/2A ±5%
10V/3A ±5%
10V/1A ±5%
Remote control
External resistance / output current ratio PAC-R series
10KΩ/3A ±5%
10KΩ/2A ±5%
10KΩ/3A ±5%
10KΩ/1A ±5%
Constant-voltage operation
CV (Green LED) lights
Constant-voltage operation
CC (Green LED) lights
Digital meter indication
Voltmeter indication
Red 3-digit LED
Max. 99.9V, fixed range
Accuracy
Output On
± (0.2% rdg + 2 digits)
Ameter indication
Red 3-digit LED
Max. 9.99A, fixed range
Accuracy
Output On
± (1.2% rdg + 2 digits)
Sampling rate
Approx. 2.5 times/ second
Functions
Output ON/OFF
Output on/off possible (Remote control is possible only for the PAC-R series)
Remote sensing
PAC-R series
Possible by using the (+S) and (-S) terminals on the panel. Compensation is possible for up to 1V one way.
Serial operation
Master / slave mode PAC-R series
One-control serial operation is possible (within the ground proof voltage)
Parallel operation
Master / slave mode PAC-R series
One-control parallel operation is possible (only for same models)
Operating conditions (Indoor use only)
Altitude
Up to 2000m
Overvoltage category
II
Polution degree
2
Operating temp. humidity range
0 to 40 °C 10 to 80%RH
Storage temperature and humidity range
-20 to 60 °C 10 to 85%RH
Cooling method
Natural alr cooling
Output polarity
+ (red), – (white), GND (Black), positive or negative grounding is possible.
BJT DC power supply PAS-3030
Call For Price
Product Description
Output increase by serial/parallel operation
The output voltage can be increased by the serial operation, while the output current can be increased by parallel operation. A one-control serial operation can be used to control several slave power supplies from one master power supply. (One-control operation is possible only for the PAS-R series.)
Output sensor terminal installed (only for the PAS-R series) under consideration of the necessity for fine setting of the load terminal voltage, an output sensor terminal has been provided on the panel surface.
Systemization by correspondence to various remote-control methods (only for the PAS-R series)
A remote-control terminal is provided for output ON/OFF by means of an external contact signal, and remote control of output voltage and the output current is possible by an external voltage of 0 to 10V and an input resistance of 0 to 10K Ω respectively.
3mV p-p
2mA
#1: The transient response denotes the response time until the voltage is stabilized when the output switch activated(on).
Share this: